(f)air tightness® Membrane EXTRA

(f)air tightness Membrane EXTRA is a reinforced airtightness and vapour control membrane designed for use in walls, ceilings and pitched roof constructions.

Its three-layer construction combines two polypropylene non-woven layers with an additional reinforcing mesh. This provides additional mechanical strength for applications where the membrane may be subjected to greater mechanical loads.

Membrane EXTRA helps form a continuous airtightness layer, reducing uncontrolled air leakage and moisture transport through the building envelope. Joints, overlaps, penetrations and connections to adjacent building elements must be sealed with suitable airtightness tapes and accessories.

PRODUCT BENEFITS

  • Reinforced three-layer construction with additional mechanical strength.
  • Combines airtightness and vapour control in one membrane.
  • Particularly suitable for consideration in constructions using heavier insulation materials, including mineral wool and cellulose.
  • High tensile and tear resistance compared with standard lightweight membranes.
  • Helps reduce uncontrolled air leakage and moisture transport by air movement through the building envelope.
  • Suitable for use with compatible airtightness tapes and sealing adhesives.
  • Can be integrated into a continuous airtightness system in suitable wall, ceiling and roof constructions.

APPLICATIONS & INSTALLATION GUIDANCE

Applications

(f)air tightness Membrane EXTRA is intended for use as an airtightness and vapour control layer in suitable wall, ceiling and pitched roof constructions.

The membrane is generally installed on the warm side of the thermal insulation. Its exact position must be appropriate for the building assembly and the intended moisture control strategy.

The reinforced construction is particularly useful where additional mechanical strength is required, including applications involving heavier insulation materials such as mineral wool, rock wool or cellulose insulation. The membrane and its fixings must not be assumed to provide structural support without appropriate verification.

Membrane Installation

  • Install the membrane across supporting members, preferably perpendicular to joists or rafters where practical.
  • Lay the membrane smoothly, avoiding unnecessary folds, creases and tension.
  • Provide sufficient overlaps for continuous sealing and adequate support behind taped joints.
  • Secure the membrane using suitable fixing methods without compromising the airtightness layer.
  • Ensure that insulation and construction loads are adequately supported.
  • Protect the installed membrane against mechanical damage during subsequent construction work.

Sealing Overlaps and Penetrations

  • Seal membrane overlaps continuously using compatible airtightness tape.
  • Press adhesive tapes firmly using a suitable application roller.
  • Avoid wrinkles, air pockets and unsupported adhesive joints.
  • Seal cable and pipe penetrations using suitable tapes or sealing grommets.
  • Repair tears, punctures and damaged areas to maintain airtightness.

Connections to Adjacent Building Elements

  • Provide continuous airtight connections to walls, floors, windows, doors and other building elements.
  • Prepare substrates to ensure reliable adhesion.
  • Where suitable, use (f)air tightness OR adhesive sealant for connections to appropriate substrates.
  • Allow movement relief or sufficient slack where necessary.
  • Avoid placing bonded joints under continuous tension.

Installation During Cold Weather

  • Work in manageable sections and complete necessary sealing before the end of each working day.
  • Check substrates for moisture, frost and condensation.
  • Observe the application temperature requirements of adhesive products and precondition cold materials where necessary.
  • Do not apply adhesive tapes to wet or frozen surfaces.

Storage and Handling

Store membrane rolls upright in dry conditions, protected from direct sunlight, excessive heat and mechanical damage.

Health, Safety and Disposal

Use appropriate care and personal protective equipment when cutting and installing membranes. Dispose of packaging and waste material in accordance with applicable local regulations.

General Installation Note

Verify the suitability and compatibility of membranes, tapes and adhesives for the intended construction. Carry out adhesion tests where necessary and protect the completed airtightness system against subsequent damage.

TECHNICAL DATA

Property Value
Product type Reinforced airtightness & vapour control membrane
Material Polypropylene, two non-woven layers with additional reinforcing mesh
Colour White with black and grey printing
Roll dimensions 1.5 × 50 m
Coverage per roll 75 m²
Mass per unit area Approx. 115 g/m² (±5%)
sd-value Approx. 20 m (TDS); ≥ 20 m (DoP)
Water vapour transmission 2–3 g/(m²·24 h)
Air permeability at 50 Pa < 0.004 m³/(m²·h)
Watertightness W1
Reaction to fire Class E
Tensile strength – MD ≥ 304 N/50 mm (DoP)
Tensile strength – CD ≥ 248 N/50 mm (DoP)
Tear resistance – MD ≥ 280 N (DoP)
Tear resistance – CD ≥ 299 N (DoP)
Elongation – MD / CD ≤ 90% / ≤ 90% (DoP)
Temperature range −40°C to +80°C; +100°C for limited exposure
UV resistance See technical data sheet*
Relevant standard EN 13984:2013
Declaration of Performance DoP 3-12122018-78 (23/09/2026)

*The technical data sheet contains differing UV-resistance information in its table and footnote. The applicable exposure period should be confirmed before prolonged UV exposure.

TECHNICAL DOCUMENTATION

Specs Membrane EXTRA

PDF – 774.9 KB 4 downloads

DoP Membrane EXTRA

PDF – 756.2 KB 10 downloads